| XS CD 01 | SECNO: 14790 |
Critical Depth occurs at 1%-annual-chance flood. Flow Code will be "C". The Ineffective flow option is used. The Ineffective Flow elevation is equal to or higher than the Critical WSEL. Please investigate whether this selection is appropriate. |
|
| XS IF 01R | SECNO: 14790 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3483.36 is higher than the ground elevation 3483.353 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3485.89. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS CD 01 | SECNO: 14480 |
Critical Depth occurs at 1%-annual-chance flood. Flow Code will be "C". The Ineffective flow option is used. The Ineffective Flow elevation is equal to or higher than the Critical WSEL. Please investigate whether this selection is appropriate. |
|
| XS IF 01L | SECNO: 14480 |
Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3473.89 is higher than the ground elevation 3472.642 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3479.01. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 13445 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3456.74 is higher than the ground elevation 3455.678 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3459.86. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS CD 01 | SECNO: 12676 |
Critical Depth occurs at 1%-annual-chance flood. Flow Code will be "C". The Ineffective flow option is used. The Ineffective Flow elevation is equal to or higher than the Critical WSEL. Please investigate whether this selection is appropriate. |
|
| XS IF 01R | SECNO: 12676 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3448.3 is higher than the ground elevation 3447.436 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3454.05. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS IF 01L | SECNO: 12676 |
Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3448.3 is higher than the ground elevation 3447.988 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3451.44. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 11803 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3438.82 is higher than the ground elevation 3438.69 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3440.75. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 11603 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3436.61 is higher than the ground elevation 3436.424 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3438.71. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 10630 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3425.45 is higher than the ground elevation 3424.78 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3427.76. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 10301 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3422.57 is higher than the ground elevation 3420.492 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3423.63. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 8703 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3404.56 is higher than the ground elevation 3402.931 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3407.73. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS IF 01L | SECNO: 8397 |
Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3400.73 is higher than the ground elevation 3400.537 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3403.29. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 8046 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3396.86 is higher than the ground elevation 3394.916 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3400.59. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 7630 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3390.81 is higher than the ground elevation 3390.597 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3399.3. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS CD 01 | SECNO: 7324 |
Critical Depth occurs at 1%-annual-chance flood. Flow Code will be "C". The Ineffective flow option is used. The Ineffective Flow elevation is equal to or higher than the Critical WSEL. Please investigate whether this selection is appropriate. |
|
| XS IF 01L | SECNO: 7034 |
Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3380.48 is higher than the ground elevation 3379.2 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3383.57. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance. |
|
| XS IF 01L | SECNO: 5045 |
Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3365.49 is higher than the ground elevation 3365.304 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3367.35. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 4778 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3364 is higher than the ground elevation 3362.215 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3373.22. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS IF 01L | SECNO: 3894 |
Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3357.32 is higher than the ground elevation 3354.385 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3361.43. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance. |
|
| XS IF 01L | SECNO: 3205 |
Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3353.95 is higher than the ground elevation 3352.18 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3357.16. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 2951 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3351.78 is higher than the ground elevation 3350.236 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3357.51. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 1522 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3342.48 is higher than the ground elevation 3341.89 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3345.45. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS IF 01R | SECNO: 1347 |
Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3341.01 is higher than the ground elevation 3338.711 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3343.57. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance. |
|
| XS CD 01 | SECNO: 223 |
Critical Depth occurs at 1%-annual-chance flood. Flow Code will be "C". The Ineffective flow option is used. The Ineffective Flow elevation is equal to or higher than the Critical WSEL. Please investigate whether this selection is appropriate. |
|
| XS IF 01L | SECNO: 223 |
Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3329.49 is higher than the ground elevation 3328.183 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3331.75. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance. |
|
| XS IF 01L | SECNO: 165 |
Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3328.92 is higher than the ground elevation 3326.945 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3330.68. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance. |
|